biocomma? Frits for Affinity Chromatography (AC) Columns

biocomma? Frits for Affinity Chromatography (AC) Columns

biocomma ® affinity chromatography column frit is specially used for affinity chromatography column after using Sepharose 4B as basis, it is widely used to extract restructuring protein, purify antibody or separate from effective constituent.
Details
biocomma ® affinity chromatography column frit is specially used for affinity chromatography column after using Sepharose 4B as basis, it is widely used to extract restructuring protein, purify antibody or separate from effective constituent.

Hydrophilic Frits

Apply for leading hydrophilic UHWMPE production technology.

biocomma ® affinity chromatography column frit, hydrophilic frit shall be moistened by water solution.

Hydrophilic frit shall have unique advantages during filtration for water solution.

Left: hydrophilic frit, droplet fast penetrates into frit; right: hydrophobic frit, droplet fails to penetrate into frit, so it must be pressurized.

Special Optimization for Affinity Chromatography Column

Frit shall be positioned at top or bottom of sorbent to prevent leaking from expensive base material.

Special optimization for affinity chromatography column assures flow rate of 1-2ml/m or 1-2droplets/s under gravity method.

Meanwhile, after comparison between such frit and other same kind of product, this shall not absorb protein after introduction to hydrophilic base group. In addition, such hydrophilic base group is hard to create air bubble during operation, herein air bubble shall reduce flow rate and make uneven base material while liquid passes by.

Notice: Flow rate still closely relates with particulate diameter and its evenness for sorbent.

Quality Control

Full traceablity use ERP management system before detailed record for each process of frit production.



biocomma ® Frits for Affinity Chromatography Column Spesc Sheet

Cat.NO. Diameter(mm) Thickness(mm) Pore(μm) DNA(mL) Package(Pcs/PK)
ACF058-16-50 5.8 1.6 50 1 1,000
ACF090-16-50 9 1.6 50 3 1,000
ACF091-16-50 9.1 1.6 50 3 1,000
ACF130-16-50 13 1.6 50 6 1,000
ACF158-16-50 15.8 1.6 50 12 1,000
ACF228-16-50 22.8 1.6 50 30 1,000
ACF266-16-50 26.6 1.6 50 60 1,000
ACF495-16-50 49.5 1.6 50 300 1,000
Custom 1-50 1.6/2.5 20/50/80 - -
Write a Comment
Comment will be posted once reviewed.
Product Category
Contact Us
Contacts : Biocomma Limited
Phone : 0086-755-25431879
Fax : 0086-755-25498726
Email : info@biocomma.com
Address : Ground FL,Bdg 12, Zhonghaixin Innovative Industrial Park,Ganli Six Rd, Buji St, Longgang Dist,Shenzhen,518114,P.R.China
舟山体彩飞鱼官方网站 平特肖精准公式 广州期货配资网 腾讯分分彩计划最准软件 青海省十一选五开奖结果 广东11选5最聪明的玩法 五分彩是全国统一吗 云南省十一选五结果 云南11先5开奖走势图 山东十一运夺金预测 传统上海快三开奖结果 期货配资公司是否合法 青海11选5前三走势图 pk10官网开奖直播 澳门快三走势图怎么破解 最近买什么股票好 一心想赢二连码